Intensification of heat exchange in two-phase thermosyphon equipped with minigap evaporator

2015/19/D/ST8/03201

Keywords

Descriptors

  • ST8_4: Mechanika ciała stałego, mechanika płynów, termodynamika
  • ST8_5: Systemy energetyczne (produkcja, dystrybucja)
  • ST8_8: Inżynieria materiałowa (biomateriały, metale, ceramika, polimery, kompozyty)

Panel

ST8 – Production and processes engineering: modelling, product design, process design and control, construction methods and engineering, power units and systems

Host institution

Politechnika Gdańska, Wydział Mechaniczny

Voivodeship: pomorskie

Other projects carried out by the institution »

Principal investigator (from the host institution)

dr Michał Eugeniusz Klugmann

Number of co-investigators in the project: 4

Call

SONATA 10 – announced on 2015-09-15

Amount awarded
385 440 PLN
Project start date
2016-10-17
Project end date
2020-04-16
Project duration
42 months (the same as in the proposal)
Project status
Project settled

Project description

Download the project description in a pdf file

Note — project descriptions were prepared by the authors of the applications themselves and placed in the system in an unchanged form.

Equipment purchased [PL]

  1. Czynniki robocze (HFE 7100, HFE 7000, R245fa lub inne) (4 pcs). Cost: 14 000 PLN
  2. Elementy obiegu termosyfonowego wraz ze skraplaczem i miniszczelinową sekcją pomiarową. Cost: 9 931 PLN
  3. Julabo F33-ME ultratermostat z funkcją grzania/chłodzenia i zewnętrznym pomiarem temperatury za pomocą czujnika Pt100. Cost: 43 640 PLN
  4. Kamera do szybkich zdjęć Rolera-XR. Cost: 3 800 PLN
  5. Konstrukcja nośna stanowiska pomiarowego. Cost: 1 074 PLN
  6. Miernik natężenia promieniowania słonecznego SOLRAD z pyranometrem CMP-3. Cost: 6 000 PLN
  7. NI PXIE-4302 +/-10V, 32-CH, 24-BIT, 5KS/S/ Voltage input module - moduł wejść do czujników prądowych i napięciowych.
  8. Pompa perystaltyczna. Cost: 14 055 PLN
  9. Pompa próżniowa ~180 l/min, dwustopniowa. Cost: 1 563 PLN
  10. Przepływomierz ultradźwiękowy GE Panametrics TransPort PT878. Cost: 19 065 PLN
  11. Przetworniki ciśnienia Trafag klasy 0.15 (10 pcs). Cost: 15 000 PLN
  12. Rezystancyjne czujniki temperatury (32 pcs). Cost: 16 000 PLN
  13. SCXI-1000 obudowa na 4 moduły firmy National Instruments wraz z akcesoriami (uchwyty, zaślepki). Cost: 4 020 PLN
  14. SCXI-1102 32-kanałowy wzmacniacz z kompensacją zimnego końca dla termopar firmy National Instruments (3 pcs). Cost: 21 780 PLN
  15. SCXI-1303 32-kanałowy moduł z wejściami termoparowymii firmy National Instruments. Cost: 1 590 PLN
  16. SCXI-1308 32-kanałowy moduł z wejściami prądowymi firmy National Instruments. Cost: 1 590 PLN
  17. SCXI-1581 32-kanałowy moduł do obsługi czujników rezystancyjnych firmy National Instruments. Cost: 10 140 PLN
  18. SCXI-1600, moduł interfejsu pomiarowego standardu USB firmy National Instruments. Cost: 5 820 PLN
  19. Stacja lutownicza. Cost: 1 197 PLN
  20. Stacja odzysku czynnika (przystosowana do pracy z czynnikami ciekłymi) MiniMax-E. Cost: 5 000 PLN
  21. Termopary typu T i J (40 pcs). Cost: 5 190 PLN
  22. Zasilacz laboratoryjny. Cost: 4 336 PLN
  23. Zestaw komputerowy, oprogramowanie, akcesoria. Integracja systemu zbierania danych pomiarowych. Cost: 15 000 PLN

Information in the final report

Publication in academic press/journals (6)

  1. Selected studies of flow maldistribution in a minichannel plate heat exchanger

    Authors:
    Dąbrowski Paweł, Klugmann Michał, Mikielewicz Dariusz
    Academic press:
    Archives of Thermodynamics (year: 2017, volume: 38/3, pages: 135 - 148), Publisher: Polish Academy of Sciences
    Status:
    Published
    DOI:
    10.1515/aoter-2017-0020 – link to the publication
  2. Pressure drop related to flow maldistribution in a model minichannel plate heat exchanger

    Authors:
    Michał Klugmann, Paweł Dąbrowski, Dariusz Mikielewicz
    Academic press:
    Archives of Thermodynamics (year: 2018, volume: 39/2, pages: 123–146), Publisher: Polish Academy of Sciences
    Status:
    Published
    DOI:
    10.1515/aoter-2018-0015 – link to the publication
  3. Flow distribution and heat transfer in minigap and minichannel heat exchangers during the flow boiling

    Authors:
    Michał Klugmann, Paweł Dąbrowski, Dariusz Mikielewicz
    Academic press:
    Applied Thermal Engineering (year: 2020, volume: 181, pages: 116034-), Publisher: Elsevier
    Status:
    Published
    DOI:
    10.1016/j.applthermaleng.2020.116034 – link to the publication
  4. Selected thermal and flow issues in a reversed thermosiphon with a steam liquid lifter

    Authors:
    Michał Klugmann, Paweł Dąbrowski, Dariusz Mikielewicz
    Academic press:
    E3S Web of Conferences 70, 02009 (year: 2018, volume: 70, pages: online), Publisher: EDP Sciences
    Status:
    Published
    DOI:
    10.1051/e3sconf/20187002009 – link to the publication
  5. Channel Blockage and Flow Maldistribution during Unsteady Flow in a Model Microchannel Plate heat Exchanger

    Authors:
    Dąbrowski Paweł, Klugmann Michał, Mikielewicz Dariusz
    Academic press:
    Journal of Applied Fluid Mechanics (year: 2019, volume: 46360, pages: 1023-1035), Publisher: JAFM
    Status:
    Published
    DOI:
    10.29252/jafm.12.04.29316 – link to the publication
  6. Flow Boiling in Minigap in the Reversed Two-Phase Thermosiphon Loop

    Authors:
    Michał Klugmann, Paweł Dąbrowski, Dariusz Mikielewicz
    Academic press:
    ENERGIES (year: 2019, volume: 46373, pages: 46044), Publisher: MDPI AG
    Status:
    Published
    DOI:
    10.3390/en12173368 – link to the publication

Articles in post-conference publications (1)

  1. Flow maldistribution in microchannel heat exchangers

    Authors:
    Klugmann Michał, Dąbrowski Paweł, Mikielewicz Dariusz
    Conference:
    XXIII Zjazd Termodynamików (year: 2017, pages: 123 - 124), Publisher: Wydawnictwo Instytutu Techniki Cieplnej, Politechnika Śląska
    Date:
    conference 19-22.09.2017
    Status:
    Published

« New search

Graphic design and implementation: Jakub Piotrowski