Ventilation, gas exchange and cardiac function in relation to intrapleural pressure changes in patients undergoing therapeutic thoracentesis
2012/05/B/NZ5/01343
Keywords
Descriptors
- NZ5_3: Patogeneza chorób człowieka
- NZ5_7: Leczenie chorób człowieka
Panel
NZ5 – Human and animal noninfectious diseases: etiology, mechanisms, diagnosis and treatment of diseases, poisonings and injuries (without neurological diseases)
Host institution
Warszawski Uniwersytet Medyczny, I Wydział Lekarski
Voivodeship: mazowieckie
Principal investigator (from the host institution)
Number of co-investigators in the project: 9
Call
OPUS 3 – announced on 2012-03-15
- Amount awarded
- 664 938 PLN
- Project start date
- 2013-06-03
- Project end date
- 2017-12-02
- Project duration
- 54 months (the same as in the proposal)
- Project status
- Project settled
Equipment purchased [PL]
- Przezskórny monitor prężności dwutlenku węgla i tlenu.. Cost: 75 000 PLN
- Spirometr z modyfikacjami producenta. Cost: 27 000 PLN
- Wytworzenie aparatury do rejestracji sygnałów podczas toracentezy, w tym do pomiaru chwilowego ciśnienia śródopłucnowego. (2 pcs). Cost: 5 154 PLN
- Zestaw komputerowy z drukarką i podstawowym oprogramowaniem.. Cost: 6 691 PLN
- komputer z oprogramowaniem. Cost: 6 000 PLN
Information in the final report
Publication in academic press/journals (10)
-
APPLICATION OF OUR ARTIFICIAL PATIENT TO INTERPRETATION AND CONTROL OF THORACENTESIS
- Authors:
- M. Michnikowski, T. Gólczewski, R. Krenke, E.M. Grabczak, K. Zielinski, K.J. Palko
- Academic press:
- Int J Artif Organs (year: 2014, volume: 37(8), pages: 627), Publisher: SAGE Publishing
- Status:
- Published
- DOI:
- 10.5301/ijao.5000347 – link to the publication
-
Cough during therapeutic thoracentesis: friend or foe?
- Authors:
- Zielinska-Krawczyk M, Michnikowski M, Grabczak EM, Palko KJ, Korczyński P, Gólczewski T, Krenke R.
- Academic press:
- Respiration (year: 2015, volume: 20, pages: 166-168), Publisher: Wiley Online Library
- Status:
- Published
- DOI:
- link to the publication
-
The use of an artificial patient in analysis of possible causes of changes in arterial blood gases during therapeutic thoracentesis.
- Authors:
- Stecka A, Michnikowski M, Grabczak E, Zielinski K, Krenke R, Zielinska-Krawczyk M, Korczynski P, Gólczewski T.
- Academic press:
- Int J Artif Organs (year: 2017, volume: 40(8), pages: 459), Publisher: SAGE Publishing
- Status:
- Published
- DOI:
- 10.5301/ijao.5000641 – link to the publication
-
Pleural pressure pulse in patients with pleural effusion: A new phenomenon registered during thoracentesis with pleural manometry
- Authors:
- Grabczak EM, Michnikowski M, Styczynski G, Zielinska-Krawczyk M, Stecka AM, Korczynski P, Zielinski K, Palko KJ, Rahman NM, Golczewski T, Krenke R.
- Academic press:
- Journal of Clinical Medicine (year: 2020, volume: 9(8), pages: 2396), Publisher: MDPI
- Status:
- Published
- DOI:
- 10.3390/jcm9082396 – link to the publication
-
The use of a virtual patient to follow pleural pressure changes associated with therapeutic thoracentesis.
- Authors:
- Gólczewski T, Stecka AM, Michnikowski M, Grabczak EM, Korczyński P, Krenke R
- Academic press:
- Int J Artif Organs (year: 2017, volume: 40, pages: 690-695), Publisher: SAGE Publishing
- Status:
- Published
- DOI:
- 10.5301/ijao.5000636 – link to the publication
-
The use of a virtual patient to follow changes in arterial blood gases associated with therapeutic thoracentesis.
- Authors:
- Stecka AM, Gólczewski T, Michnikowski M, Grabczak EM, Zieliński K, Zielińska- Krawczyk M, Korczyński P, Krenke R.
- Academic press:
- Int J Artif Organs (year: 2018, volume: 41(11), pages: 690-697), Publisher: SAGE Publishing
- Status:
- Published
-
Pleural manometry in patients with pleural diseases – the usefulness in clinical practice.
- Authors:
- Grabczak EM, Krenke R, Zielinska-Krawczyk M, Light RW.
- Academic press:
- Respiratory Medicine (year: 2018, volume: 145, pages: 230-236), Publisher: Elsevier
- Status:
- Published
- DOI:
- 10.1016/j.rmed.2018.01.014 – link to the publication
-
Pleural manometry – historical background, rationale for use, and methods of measurement.
- Authors:
- Zielinska-Krawczyk M, Krenke R, Grabczak EM, Light RW.
- Academic press:
- Respiratory Medicine (year: 2018, volume: 136, pages: 21-28), Publisher: Elsevier
- Status:
- Published
- DOI:
- 10.1016/j.rmed.2018.01.013 – link to the publication
-
Therapeutic thoracentesis-impact on respiratory rate and intrapleural pressure amplitude change.
- Authors:
- Grabczak EM, ZielińskaKrawczyk M, Michnikowski M, Zieliński K, Korczyński P, Stecka AM, Gólczewski T, Krenke R.
- Academic press:
- Eur Respir J (year: 2017, volume: 50, pages: PA3753), Publisher: European Respiratory Society
- Status:
- Published
- DOI:
- 10.1183/1393003.congress-2017.PA3753 – link to the publication
-
Patterns of pleural pressure amplitude and respiratory rate changes during therapeutic thoracentesis.
- Authors:
- Zielinska-Krawczyk M, Grabczak EM, Michnikowski M, Zielinski K, Korczynski P, Stecka A, Golczewki T, Krenke R
- Academic press:
- BMC Pulmonary Medicine (year: 2018, volume: 18(1), pages: 36), Publisher: BioMed Central (Springer Nature)
- Status:
- Published
- DOI:
- 10.1186/s12890-018-0595-7 – link to the publication