Projects funded by the NCN


Information on the principal investigator and host institution

Information of the project and the call

Keywords

Equipment

Delete all

Low noise pixel integrated electronics dedicated to recording neurobiological signals.

2011/01/N/ST7/01256

Keywords:

front end electronics multi channel pixel architecture submicron process neurobiological signals

Descriptors:

  • ST7_11: Electronic, optoelectronic and photonic components and systems for applications (e.g. in biomedical engineering)

Panel:

ST7 - Systems and communication engineering: electronics, communication, optoelectronics

Host institution :

AGH w Krakowie, Wydział Elektrotechniki, Automatyki Informatyki i Inżynierii Biomedycznej

woj.

Other projects carried out by the institution 

Principal investigator (from the host institution):

dr Piotr Kmon 

Number of co-investigators in the project: 2

Call: PRELUDIUM 1 - announced on 2011-03-15

Amount awarded: 271 700 PLN

Project start date (Y-m-d): 2011-12-07

Project end date (Y-m-d): 2014-11-06

Project duration:: 35 months (the same as in the proposal)

Project status: Project settled

Equipment purchased [PL]

  1. nie planowano zakupu aparatury.

Information in the final report

  • Publication in academic press/journals (5)
  • Articles in post-conference publications (11)
  1. Efficient neural amplifiers using MOS and MIM capacitors in 180 nm CMOS process
    Authors:
    P. Kmon, P. Gryboś, R. Szczygieł, M. Żołądź
    Academic press:
    Elektronika, Konstrukcje, Technologie, Zastosowania (rok: 2012, tom: 5, strony: 5), Wydawca: Elektronika, Konstrukcje, Technologie, Zastosowania
    Status:
    Published
  2. Analiza szumowa kanału odczytowego przeznaczonego do wielokanałowych układów scalonych dedykowanych do eksperymentów neurobiologicznych (poszerzona praca z wystapienia na Warsztatach Doktoranckich)
    Authors:
    P.Kmon, P. Otfinowski
    Academic press:
    Informatyka Automatyka Pomiary w Gospodarce i Ochronie Środowiska (rok: 2013, tom: nr 1, strony: 3), Wydawca: Informatyka Automatyka Pomiary w Gospodarce i Ochronie Środowiska
    Status:
    Published
  3. Wielokanałowy układ scalony do zło żłonych eksperymentów neurobiologicznych (poszerzony artykuł z konferencji Modelowanie i Symulacja Systemów Pomiarowych)
    Authors:
    P.Kmon
    Academic press:
    Pomiary, Automatyka, Kontrola (rok: 2012, tom: vol. 58, strony: 4), Wydawca: Pomiary, Automatyka, Kontrola
    Status:
    Published
  4. Digitally Assisted Neural Recording and Spike Detection Multichannel Integrated Circuit Designed in 180nm CMOS Technology
    Authors:
    P. Kmon
    Academic press:
    Micorelectronics Journal (rok: 2014, ), Wydawca: Elsevier
    Status:
    Submitted
    DOI:
    10.1016/j.mejo.2014.04.031 - link to the publication
  5. Energy Efficient Low-Noise Multichannel Neural Amplifier in Submicron CMOS Process
    Authors:
    P. Kmon, P. Gryboś
    Academic press:
    IEEE Transactions on Circuits and Systems—I: Regular Papers (rok: 2013, tom: Vol. 60, No. 7, strony: 12), Wydawca: Regular Papers
    Status:
    Published
    DOI:
    10.1109/TCSI.2012.2230504 - link to the publication
  1. Neural Recording and Spike Detection Multichannel Integrated Circuit for Broad Range of Biomedical Signals Recording
    Authors:
    P.Kmon, P.Grybos, R.Szczygieł, M.Zoladz, , San Diego, USA
    Conference:
    IEEE EMBS Conference on Neural Engeenering (rok: 2013, ), Wydawca: IEEE EMBS Conference on Neural Engeenering
    Data:
    konferencja 41579
    Status:
    Published
  2. Wielokanałowy układ scalony do złożonych eksperymentówneurobiologicznych
    Authors:
    P. Kmon
    Conference:
    Modelowanie i Symulacja Systemów Pomiarowych (rok: 2012, ), Wydawca: AGH
    Data:
    konferencja maj 2012
    Status:
    Published
  3. CMRR Improvement for Multichannel Integrated Recording Circuits Processed in Submicron Technologies Dedicated to Neurobiology Experiments
    Authors:
    P. Kmon
    Conference:
    MIXDES 2014, Mixed design of integrated circuits and systems (rok: 2014, ), Wydawca: MIXDES
    Data:
    konferencja czerwiec 2014
    Status:
    Published
  4. Effective Noise Minimization in Multichannel Recording Circuits Processed in Modern Technologies for Neurobiology Experiments
    Authors:
    P. Kmon, P. Gryboś, M. Żołądź, R. Szczygieł
    Conference:
    IEEE BioCAS 2014 (rok: 2014, ), Wydawca: IEEE BioCAS 2014
    Data:
    konferencja 41944
    Status:
    Published
  5. Area Efficient Low Power Neural Amplifiers Using MOS and MIM Capacitors in Submicron Technologies for Ultra Low Corner Frequencies
    Authors:
    P.Kmon, P.Grybos, R.Szczygiel, M.Zoladz,
    Conference:
    MIXDES 2012, 19th International Conference "Mixed Design of Integrated Circuits and Systems" (rok: 2012, ), Wydawca: MIXDES 2012
    Data:
    konferencja May 24-26, 2012
    Status:
    Published
  6. NRSD8 - Neural Recording and Spike Detection Multichannel Integrated Circuit Designed in 180nm CMOS Technology
    Authors:
    P.Kmon
    Conference:
    MIXDES 2013, 20th International Conference "Mixed Design of Integrated Circuits and Systems" (rok: 2013, ), Wydawca: MIXDES 2013
    Data:
    konferencja June, 2013
    Status:
    Published
  7. ANALIZA SZUMOWA KANAŁU ODCZYTOWEGO PRZEZNACZONEGO DO WIELOKANAŁOWYCH UKŁADÓW SCALONYCH DEDYKOWANYCH DO EKSPERYMENTÓW NEUROBIOLOGICZNYCH (prezentacja na konferencji)
    Authors:
    P. Kmon, P.Otfinowski
    Conference:
    Warsztaty Doktoranckie oraz letnia szkoła metod numerycznych (rok: 2012, ), Wydawca: Warsztaty Doktoranckie Lublin
    Data:
    konferencja Warsztaty Doktoranckie Lublin
    Status:
    Published
  8. Family of Mulitchannel ASICs for Measurements Electrical Activity of Neural Network
    Authors:
    P. Grybos, M. Zoladz, P. Kmon, R. Szczygiel
    Conference:
    CDNLive! EMEA 2012 (rok: 2012, ), Wydawca: CDNLive! EMEA 2012
    Data:
    konferencja Munich May 2012
    Status:
    Published
  9. Front-end amplifier optimization for integrated circuits fabricated in the submicron processes dedicated to the neurobiology experiments
    Authors:
    P. Kmon, P. Otfinowski
    Conference:
    EMBC 2012 San Diego : 34th annual international conference of the IEEE Engineering in Medicine and Biology Society (rok: 2012, ), Wydawca: EMBC 2012 San Diego
    Data:
    konferencja 28 August – 1 September, 2012
    Status:
    Published
  10. Design of a Reconfigurable Stimulator for Multichannel Integrated Systems Dedicated to Neurobiology Experiments
    Authors:
    P. Kmon
    Conference:
    MIXDES 2014, Mixed design of integrated circuits and systems (rok: 2014, ), Wydawca: MIXDES
    Data:
    konferencja czerwiec 2014
    Status:
    Published
  11. High uniformity of the main parameters of the integrated electronics dedicated to record broad range of the biopotentials
    Authors:
    P.Kmon, M.Żołądź, P.Gryboś, R.Szczygieł
    Conference:
    International Meeting on Substrate-Integrated Microelectrode Arrays (rok: 2012, ), Wydawca: International Meeting on Substrate-Integrated Microelectrode Arrays
    Data:
    konferencja 41061
    Status:
    Published