Projects funded by the NCN


Information on the principal investigator and host institution

Information of the project and the call

Keywords

Equipment

Delete all

99m-Tc internal contaminations among nuclear medicine medical personnel during ventilation-perfusion SPECT lung scan,

2018/31/D/NZ7/02217

Keywords:

technetium internal contamination dosimetry medical personnel

Descriptors:

  • NZ7_6: Occupational medicine
  • NZ7_12: Prevention of human diseases
  • NZ7_4: Prevention in population health

Panel:

NZ7 - Diagnostic tools, therapies and public health: public health, epidemiology, environmental health risks and occupational medicine, medical ethics, drug discovery and therapies, pharmacology

Host institution :

Instytut Fizyki Jądrowej im. Henryka Niewodniczańskiego Polskiej Akademii Nauk

woj. małopolskie

Other projects carried out by the institution 

Principal investigator (from the host institution):

dr Kamil Brudecki 

Number of co-investigators in the project: 2

Call: SONATA 14 - announced on 2018-09-14

Amount awarded: 108 700 PLN

Project start date (Y-m-d): 2019-07-05

Project end date (Y-m-d): 2022-07-04

Project duration:: 36 months (the same as in the proposal)

Project status: Project settled

Project description

Download the project description in a pdf file

Note - project descriptions were prepared by the authors of the applications themselves and placed in the system in an unchanged form.

Equipment purchased [PL]

  1. Autonomiczny liczniki promieniowania gamma (24 000 PLN)

Information in the final report

  • Publication in academic press/journals (4)
  1. 99m-Tc internal contaminations measurements among nuclear medicine medical personnel during ventilation – perfusion SPECT lung scans
    Authors:
    E. Borkowska, K. Brudecki, M. Kostkiewicz, K. Gorzkiewicz, R. Misiak, E. Nalichowska, J. Miszczyk, T. Mróz
    Academic press:
    Radiation and Environmental Biophysics (rok: 2021, tom: -, strony: -), Wydawca: Springer
    Status:
    Published
    DOI:
    10.1007/s00411-021-00905-x - link to the publication
  2. Reduction of radioactive internal contamination 99mTc among the medical personnel of nuclear medicine facilities with the use of respiratory track protection measures
    Authors:
    K. Brudecki, E. Borkowska, K. Gorzkiewicz, M. Kostkiewicz, R. Misiak, T. Mróz, E. Nalichowska
    Academic press:
    Journal of Radioanalytical and Nuclear Chemistry (rok: 2022, tom: -, strony: -), Wydawca: Springer
    Status:
    Submitted
  3. Genotoxicity Associated with 131I and 99mTc Exposure in Nuclear Medicine Staff: A Physical and Biological Monitoring Study,
    Authors:
    J. Miszczyk, A. Gałaś, A. Panek, A. Kowalska, M. Kostkiewicz, E. Borkowska, K. Brudecki,
    Academic press:
    Cells (rok: 2022, tom: 11, strony: -), Wydawca: MDPI
    Status:
    Published
    DOI:
    https://www.mdpi.com/2073-4409/11/10/1655; - link to the publication
  4. Low-background, digital gamma-ray spectrometer with BEGe detector and active shield: commissioning, optimisation and software development
    Authors:
    K. Gorzkiewicz, J.W. Mietelski, R. Kierepko, K. Brudecki
    Academic press:
    Journal of Radioanalytical and Nuclear Chemistry (rok: 2019, tom: 322, strony: 1311-1321), Wydawca: Springer
    Status:
    Published
    DOI:
    10.1007/s10967-019-06853-7 - link to the publication