Projects funded by the NCN


Information on the principal investigator and host institution

Information of the project and the call

Keywords

Equipment

Delete all

Immunochemical strategies of iron's homeostasis monitoring under flow analysis conditions

2016/21/D/ST4/00924

Keywords:

Iron's homeostasis Transferrin Transferrin receptor Ferritin Flow analysis Clinical analysis

Descriptors:

  • ST4_8: Organic chemistry
  • ST4_6: Instrumental methods in chemistry

Panel:

ST4 - Chemistry: physical chemistry/chemical physics, theoretical chemistry, analytical chemistry, inorganic chemistry, organic chemistry, method development

Host institution :

Uniwersytet Warszawski, Wydział Chemii

woj. mazowieckie

Other projects carried out by the institution 

Principal investigator (from the host institution):

dr Kamil Strzelak 

Number of co-investigators in the project: 3

Call: SONATA 11 - announced on 2016-03-15

Amount awarded: 474 200 PLN

Project start date (Y-m-d): 2017-01-25

Project end date (Y-m-d): 2021-01-24

Project duration:: 48 months (the same as in the proposal)

Project status: Project settled

Project description

Download the project description in a pdf file

Note - project descriptions were prepared by the authors of the applications themselves and placed in the system in an unchanged form.

Equipment purchased [PL]

  1. Pompa strzykawkowa (11 045 PLN)
  2. Zawór (16 063 PLN)
  3. Pompa perystaltyczna (13 997 PLN)
  4. Wirówka (14 000 PLN)
  5. Frezarka,pilarka i szlifierko-polerka (8 842 PLN)

Information in the final report

  • Publication in academic press/journals (5)
  • Book publications / chapters in book publications (1)
  1. A comparison of photometric methods for serum iron determination under flow analysis conditions
    Authors:
    Natalia Rybkowska, Kamil Strzelak, Robert Koncki
    Academic press:
    Sensors and Actuators B: Chemical (rok: 2018, tom: 254, strony: 307–313), Wydawca: Elsevier
    Status:
    Published
    DOI:
    10.1016/j.snb.2017.07.059 - link to the publication
  2. 3D printed silicone platforms with laser-scattering protein detection under flow analysis conditions as a development of Silicone Optical Technology (SOT)
    Authors:
    Kamil Strzelak, Chacriya Malasuk, Yuji Oki, Kinichi Morita, Ryoichi Ishimatsu
    Academic press:
    Microchemical Journal (rok: 2020, tom: 157, strony: 104936), Wydawca: Elsevier
    Status:
    Published
    DOI:
    10.1016/j.microc.2020.104936 - link to the publication
  3. Towards mechanized biparametric ceruloplasmin assay
    Authors:
    Kamil Strzelak, Justyna Głowacka, Robert Koncki
    Academic press:
    Talanta (rok: 2020, tom: 214, strony: 120881), Wydawca: Elsevier
    Status:
    Published
    DOI:
    10.1016/j.talanta.2020.120881 - link to the publication
  4. A remote-controlled immunochemical system for nephelometric detection of human serum transferrin
    Authors:
    Kamil Strzelak, Robert Koncki
    Academic press:
    Biosensors and Bioelectronics (rok: 2019, tom: 127, strony: 31-37), Wydawca: Elsevier
    Status:
    Published
    DOI:
    10.1016/j.bios.2018.12.011 - link to the publication
  5. The comparison between light-scattering detectors based on LED and photodiode for immunoprecipitation assays of transferrin and ferritin
    Authors:
    Kamil Strzelak, Agnieszka Czajkowska, Robert Koncki
    Academic press:
    Analytica Chimica Acta (rok: 2021, tom: 1175, strony: 338753), Wydawca: Elsevier
    Status:
    Published
    DOI:
    10.1016/j.aca.2021.338753 - link to the publication
  1. Flow analysis strategies for examination of iron storage and distribution in human serum
    Authors:
    Kamil Strzelak, Natalia Rybkowska
    Book:
    Flow and capillary electrophoretic analysis (rok: 2018, tom: -, strony: 97-120), Wydawca: Nova Science Publishers, Inc.
    Status:
    Published