The methods and the algorithms of lung structures and pathophysiology monitoring in the model of recruitment during acute respiratory distress syndrome.
2013/11/B/ST7/01173
Keywords
Descriptors
- ST7_11: Inżynieria biomedyczna
Panel
ST7 – Systems and communication engineering: electronics, communication, optoelectronics
Host institution
Politechnika Wrocławska, Wydział Elektroniki.
Voivodeship: dolnośląskie
Principal investigator (from the host institution)
Number of co-investigators in the project: 5
Call
OPUS 6 – announced on 2013-09-16
- Amount awarded
- 631 680 PLN
- Project start date
- 2014-08-14
- Project end date
- 2017-10-13
- Project duration
- 38 months (the same as in the proposal)
- Project status
- Project settled
Equipment purchased [PL]
- Gazometr kliniczny GEM 4000. Cost: 70 000 PLN
- Kardiomonitor VP-1200.. Cost: 20 000 PLN
- Tomograf impedancyjny Swisstom AG.. Cost: 30 000 PLN
Information in the final report
Publication in academic press/journals (3)
-
Analysis of the method for ventilation heterogeneity assessment using the Otis model and forced oscillations
- Authors:
- Jarosław Glapinski, Janusz Mroczka, Adam G. Polak
- Academic press:
- Computer Methods and Programs in Biomedicine (year: 2015, volume: 122, pages: 330-340), Publisher: Elsevier
- Status:
- Published
- DOI:
- 10.1016/j.cmpb.2015.08.017 – link to the publication
-
Minimization of ventilator-induced lung injury in ards patients – part i: complex model of mechanically ventilated ards lungs.
- Authors:
- Jarosław Glapiński, Ireneusz Jabłoński
- Academic press:
- METROLOGY AND MEASUREMENT SYSTEMS (year: 2017, volume: Vol. 24 No. 4, pages: 685-699), Publisher: POLISH ACADEMY OF SCIENCES Committee on Metrology and Scientific Instrumentation
- Status:
- Published
- DOI:
- 10.1515/mms-2017-0053 – link to the publication
-
Neutrophil response and oxidant/antioxidant balance during mechanical ventilation, lung injury and recruitment using whole body external negative pressure. An experimental study
- Authors:
- Wessely-Szponder J, Szponder T, Fijalkowska-Nestorowicz A, Bobowiec
- Status:
- Accepted for publication
Articles in post-conference publications (3)
-
Haemodynamics during end-expiratory positive pressure and external negative pressure in a porcine model of lung injury.
- Authors:
- A. Fijałkowska-Nestorowicz, J. Glapiński, J. Wośko
- Conference:
- 30th Annual Congress of the European Society of Intensive Care Medicine (year: 2017, pages: (Suppl. 2): 62-63), Publisher: Springer Intensive Care Medicine Experimental
- Date:
- conference 23-27 Wrzesień 2017
- Status:
- Published
- DOI:
- link to the publication
-
Effect of external negative pressure versus positive end-expiratory pressure on respiratory mechanics during recruitment of experimentally induced lung injury.
- Authors:
- A. Nestorowicz, A. Fijałkowska-Nestorowicz, J. Glapiński, J. Wośko
- Conference:
- 30th Annual Congress of the European Society of Intensive Care Medicine (year: 2017, pages: vol 5 (Suppl. 2): 1-2), Publisher: Springer Intensive Care Medicine Experimental
- Date:
- conference 23-27 Wrzesień 2017
- Status:
- Published
- DOI:
- link to the publication
-
Low frequency forced oscillation technique in lung recruitment maneuver monitoring.
- Authors:
- J. Glapinski, J. Mroczka, A. Nestorowicz, A. Fijalkowska-Nestorowicz
- Conference:
- 37th International Symposium on Intensive Care and Emergency Medicine (year: 2017, pages: 26), Publisher: Springer
- Date:
- conference 21-24 marzec 2017
- Status:
- Published
- DOI:
- link to the publication
Book publications / chapters in book publications (1)
-
Sieć złożona jako narzędzie poznania w metrologii.
- Authors:
- JABŁOŃSKI I.
- Book:
- Sieć złożona jako narzędzie poznania w metrologii. (year: 2015, volume: 0, pages: 0), Publisher: Oficyna Wydawnicza Politechniki Wrocławskiej
- Status:
- Published